How to deal with common failures of small and medium-sized pharmaceutical purified water equipment-O

How to deal with common failures of small and medium-sized pharmaceutical purified water equipment?

by:Ocpuritech     2021-06-23
How small and medium sized pharmaceutical water purification equipment Troubleshooting author of the article:? We after buying the small and medium sized pharmaceutical water purification equipment is not once and for all, the daily also need proper maintenance and maintenance measures. If the equipment is not cleaned and maintained on a regular basis, small and medium-sized pharmaceutical purified water equipment sometimes has the following failures, which affects work efficiency. During long-term operation of small and medium-sized pharmaceutical purified water equipment. It is inevitable that there will be some minor faults. Users do not need to panic. They only need to confirm the cause of the fault and take corresponding measures to avoid further damage to the small and medium-sized pharmaceutical purified water equipment. Here is a brief introduction to how to solve the failure of small and medium-sized pharmaceutical purified water equipment. 1. Reasons for the difficulty in starting small and medium-sized pharmaceutical purified water equipment: 1. The raw water pressure is low and the flow is insufficient. 2. The solution to the blockage of the fine filter element in the security filter: 1. Start the booster pump or increase the original water tank. 2. Replace the fine filter element 2. Reasons for the high conductivity of the pure water at the initial startup of the small and medium-sized pharmaceutical purified water equipment: 1. It is caused by the anticorrosive liquid in the membrane. 2. The working pressure is not in the rated range and the membrane pressure regulating valve is closed. Solution: 1. Flush the RO membrane for 30-60 minutes. 2. Adjust the working pressure to the rated range but do not close the regulating valve. Third, the water quality of the pharmaceutical purified water equipment is not good or there is a peculiar smell. Reason: The adsorption capacity of activated carbon cannot effectively absorb the peculiar smell and residual chlorine in the water. Solution: Replace the activated carbon filter. RO membrane with high raw water hardness is easy to scale. 2. The water temperature is low, and the water production drops normally. 3. The RO membrane is contaminated by organic matter. Solution: 1. Equipped with an automatic water softener and clean the RO membrane. 2. The incoming water can be heated, and it should not exceed 45°C. 3. Clean the RO membrane with B-type cleaning agent. 5. Reasons for abnormal operation of small and medium-sized pharmaceutical purified water equipment: electrical components may be damaged. Solution: refer to the circuit diagram to check the components and troubleshoot. The above content is some common faults summarized based on years of engineering experience, as well as related solutions, users can save This article facilitates the timely solution of problems in the application of small and medium-sized pharmaceutical purified water equipment.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...
WhatsAPP图标