What are the maintenance methods for pipelines of automatic desalination equipment-Ocpuritech-img

What are the maintenance methods for pipelines of automatic desalination equipment?

by:Ocpuritech     2021-06-04
What are the maintenance methods for pipelines of automatic desalination equipment? Author: desalination equipment in long-term use, pipeline equipment will breed some bacteria, then you need to pipeline disinfection cleaning work to do in order to ensure water quality is safe, small series to introduce facet What are the disinfection methods for seawater desalination equipment pipelines? 1. 3% hydrogen peroxide preparation: turn on the seawater desalination equipment, prepare pure water into the cleaning tank (do not enter the pure water tank), inject pure water (250L), add 30% 50L hydrogen peroxide to the cleaning tank, and make 6% After the hydrogen peroxide solution, it is transported to the pure water storage tank through the cleaning pump. After delivery, pure water (200L) is injected into the cleaning tank and delivered to the pure water storage tank so that the concentration of hydrogen peroxide in the pure water storage tank is 3% and the volume is 500L. 2. Disinfection: Turn on the pure water pump, make the 3% hydrogen peroxide disinfectant circulate in the pure water tank and pipeline for 30 minutes, and circulate the inner wall of the storage tank through a spray ball. 3. Disinfectant discharge: After the 3% hydrogen peroxide cycle is over, open the valve at each point of use of pure water to make it in a half-open state, so that the disinfectant can disinfect the valve until the disinfectant is exhausted. (When the disinfectant cannot be drained, the pure water pump should be turned off, and the drain valve of the pure water storage tank should be opened to drain the disinfectant). 4. Pure water final flushing: when starting the water system to prepare pure water into the pure water storage tank, start the pure water pump, and after 30 minutes of circulating and flushing the storage tank and pipeline, open the pure water storage tank drain valve and each valve for use. Empty. The above is the method of disinfection of the pipeline of the automatic seawater desalination equipment. I hope it will be helpful to everyone. Regularly disinfect the pipeline of the seawater desalination equipment to ensure the quality of the effluent. If you have any questions, you can leave a message to us at any time.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...
WhatsAPP图标